Gas Inserts
E33 Gas Insert
E33 Gas Insert
Model
E33-NG1
Natural Gas
E33-LP1
Fuel Type
Propane
Minimum Supply Pressure
Manifold Pressure - High
Manifold Pressure - Low
Orifice Size -Altitude 0-4500 ft.
5” W.C. (1.25 kPa)
3.8” W.C. (0.95 kPa)
1.1” W.C. (0.27 kPa)
#31 DMS
12” W.C. (2.99 kPa)
11” W.C. (2.74 kPa)
2.9” W.C. (0.72 kPa)
#50 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
20,000 BTU/h
(5.86 kW)
19,000 BTU/h
(5.57 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
38,000 BTU/h
(11.14 kW)
35,500 BTU/h
(10.40 kW)
Vent Sizing
3” Co-linear
3” Co-linear
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
A
Minimum Fireplace Dimensions
B
The minimum fireplace dimensions for the FPI gas fireplace insert are
shown in the following diagrams:
C
G
F
30°
M
L
J
H
D
E
K
N
Dimension Description
E33
A
B
C
D
E
F
G
H
I
Faceplate Width
Faceplate Height
Unit Width
45-9/16” (1157mm)
31-1/8” (791mm)
32-1/4” (819mm)
23-13/16” (605mm)
16-3/4” (426mm)
11-1/4” (286mm)
1-3/8” (35mm)
23” (583mm)
Dimension Description
Contour Faceplate
24-3/16” (614mm)
32-1/4” (819mm)
17” (432mm)
Unit Height
J
Height
Unit Depth
K
L
Width
Faceplate to Vent Centerline
Faceplate Depth
Depth
M
N
Max. Lintel Bar Depth
Rear Width
8” (203mm)
Height to Vent Collar
25” (635mm)
Optional or Standard Front Depth
N/A
June 2007 Regency Product Specifications Book
127
|
Pyramid Technologies CD Player CDR22P User Guide
Radio Shack Two Way Radio TRC 239 User Guide
RCA CRT Television F32648 User Guide
Reebok Fitness Treadmill RBTL18921 User Guide
Rotel Stereo Receiver RSX 965 User Guide
Samsung Network Card MP 80S User Guide
Sanyo Microwave Oven EM S5597B User Guide
Sanyo Projector PLV 75 User Guide
Seiko eBook Reader WP5402R User Guide
Sennheiser Headphones 504046 User Guide